Verified OmniStudio-Developer dumps Q&As 100% Pass in First Attempt Guaranteed Updated Dump from ITExamDownload
Pass Salesforce Developer OmniStudio-Developer Exam With 88 Questions
The Salesforce OmniStudio-Developer Certification Exam is a comprehensive exam that tests a developer's knowledge of the Salesforce OmniStudio platform. This certification is highly respected in the industry and is recognized by organizations around the world. It is designed to ensure that developers have the knowledge and skills necessary to build effective solutions on the platform. If you are a developer who wants to demonstrate your expertise in building solutions on the Salesforce platform, the OmniStudio-Developer certification is an excellent credential to have.
NEW QUESTION # 37
On a FlexCard canvas, several fields display with Salesforce data, but one of the fields shows only the label. What could cause this?
- A. The field name in the FlexCard state does not match the DataRaptor Extract's Output JSON Path name.
- B. In the Setup Pabel, {recordId} is misspelled in the Data Source Input Map.
- C. There are No test Data test Parameters configured.
- D. In the FlexCard state, the Field type for the field does not match the type in the Salesforce record.
Answer: C
NEW QUESTION # 38
In an Integration Procedure, you need to perform a multi-step calculation on every element of an array. Based on best practices, what two methods are recommended? Choose 2 answers
- A. Use a Calculation Action to call a Calculation Procedure.
- B. Use a Set Values Element inside a Loop Block.
- C. Use a Matrix Action to call a Calculation Matrix
- D. Use a List Action to merge the array elements together.
Answer: A,C
NEW QUESTION # 39
In an OmnoScript, a developer needs to configure a Disclosure element to require user input only if the user already checked a Non-Disclosure Agreement Checkbox.
How should the developer configure the conditional view to meet this requirement?
- A. Set element to require if true
- B. Disable read only if true
- C. Set element to optional if false
- D. Show element if true
Answer: D
NEW QUESTION # 40
What is the reason for this? Refer to the exhibit below.
- A. A developer failed to include a Navigate Action Element to pass data from the parent OmniScript.
- B. Both parent and embeddedOmniScripts have the same element name for the Set Values element.
- C. The flag passData.JSON in the parent OmniScript in not configured correctly.
- D. The WLC PubSub Messge flag in the Set Values action of the parent OmniScript has not been set.
Answer: A
NEW QUESTION # 41
A developer is troubleshooting an Integration Procedure with two elements: A Remote Action named FetchCart and a Response Action named ResponseCart.
In Preview, what JSON node shows the data sent to the Response Action?
- A. ResponseCartDebug
- B. ResponseCart
- C. FetchCart
- D. Response
Answer: A
NEW QUESTION # 42
A developer needs to limit the of a DataRaptor Extract to a maximum of one result.
How should the developer configure this?
- A. Use a Custom Output Type when creating the DataRaptor
- B. Set the Limit Property on the Action that calls the DataRaptor Extract.
- C. Use the LIMIT filter on the Extract definition
- D. Define a formula with the Filter function
Answer: C
NEW QUESTION # 43
In an OmnoScript, a developer needs to configure a Disclosure element to require user input only if the user already checked a Non-Disclosure Agreement Checkbox.
How should the developer configure the conditional view to meet this requirement?
- A. Set element to require if true
- B. Set element to optional if false
- C. Disable read only if true
- D. Show element if true
Answer: C
NEW QUESTION # 44
A healthcare company wants to enable its subscribers to add, edit, or delete dependents related to their policy Community portal. The developer on the project decides to use an MniScript.
How should the developer configure the OmniScript to provide this functionality?
- A. Use an Edit Block element configured with Remote Actions.
- B. Use an Input Block element and a DataRaptor Post Action element.
- C. Use an Edit Block element configured with SOQL statements.
- D. Use a Text Block element and a Remote Action element.
Answer: A
NEW QUESTION # 45
Refer to the exhibit.
What JSON code correct represent the step in the OmniScript Structure panel shown?
A)
B)
C)
D)
- A. Option D
- B. Option A
- C. Option B
- D. Option C
Answer: D
NEW QUESTION # 46
Which three are true about Calculation Matrix inputs? Choose 3 answers
- A. They can be a combination of values.
- B. They can represent ranges.
- C. They must contain numerical data.
- D. They must be unique.
Answer: A,B,D
NEW QUESTION # 47
A developer needs to create a list of cases for an account in a single Datable in a FlexCard. Like the one shown below.
How can the developer configure the FlexCard to display the case records in this way?
- A. Enable the Repeat Records feature on the FlexCard Setup tab
- B. Select the Repeatable Mode property on the data table elements
- C. Enable the record Looping feature on the data table elements
- D. Disable the Repeat Record feature on the FlexCard setup tab
Answer: D
NEW QUESTION # 48
A developer need to configure a calculation procedure to calculation a subtotal using two different depending on whether the input Boolean variable is Customer is set to true or false.
How should a developer configure the calculation procedure to conditionally execute the correct formula?
- A. Use two separate Calculation Steps with the Conditional Step property selected: compare the isCustomer variable directly to the literal true and false values in the Condition syntax.
- B. Use a single Calculation Steps with IF statement directly in the formula definition to reference the isCustome variable and conditionally perform the appropriate calculation.
- C. Use two separate Calculation Steps with the Conditional Step property selected: reference just the isCustomer variable in the Conditional syntax (no comparison necessary)
- D. Use two separate Calculation Steps with the Conditional Step property selected: use the ISTRUE(isCustomer) and NOT (ISTRUE) (isCustomer) functions in the Condition syntax.
Answer: C
NEW QUESTION # 49
A developer creates an OmniScript to update billing information. After analyzing the different types of customer interactions that occur at the company, the developer determines updating billing information should be included in the majority of customer interactions, which are represented by more than 20 different FlexCards.
What is the most efficient way for the developer to configure the action that invokes the OmniScript?
- A. As an OmniStudio Action
- B. As an OS Action
- C. As a Custom Action
- D. As a Lightning Action
Answer: B
NEW QUESTION # 50
A)
B)
- A. Option A
- B. Option B
Answer: A
NEW QUESTION # 51
A developer needs to build a DataRaptor Transform to send current weather to both an OmniScript Card Layout. Which of these samples would be valid for the Expected Output JSON?
A)
B)
C)
D)
- A. Option A
- B. Option D
- C. Option C
- D. Option B
Answer: B
NEW QUESTION # 52
Refer to the exhibit.
The card layout uses an integration Procedure as a data source. The cards use the layout data source.
Which JSON data structure supports this card layout and follows best practices?
A)
B)
C)
- A. Option A
- B. Option B
- C. Option C
Answer: C
NEW QUESTION # 53
A developer creates an OmniScript to update billing information. After analyzing the different types of customer interactions that occur at the company, the developer determines updating billing information should be included in the majority of customer interactions, which are represented by more than 20 different FlexCards.
What is the most efficient way for the developer to configure the action that invokes the OmniScript?
- A. As a Custom Action
- B. As a Lightning Action
- C. As an OmniStudio Action
- D. As an OS Action
Answer: C
NEW QUESTION # 54
An OmniScript updates data from one Salesforce record, but when it completes, only some of the data is updated in Salesforce. A DataRaptor Load saves the dat a. What error could cause this behavior?
Choose 2 answers
- A. The fields that are not updated are read only in Salesforce.
- B. ContextId is misspelled in the merge code that passes the Recordld to the DataRaptor
- C. In the DataRaptor Load, in the Preview tab, the Record is from the wrong record type.
- D. The input JSON paths In the DataRaptor Load do not match the JSON from the OmniScript.
Answer: A,D
NEW QUESTION # 55
Refer to the exhibit below. What JSON from the DRGetContactDeteils action would display all six values correctly in the shown? BlkCases is a Repeat Block, and the names of the elements are the same as the label names without spaces.
A)
B)
C)
D)
- A. Option A
- B. Option D
- C. Option C
- D. Option B
Answer: A
NEW QUESTION # 56
in an OmniScript, you need to get data from a single field ina Salesforce record.
What element does this?
- A. DataRaptor Post Action
- B. Select
- C. HTTP Action
- D. Lookup
Answer: D
NEW QUESTION # 57
Refer to the exhibit below.
What is the reason that the fields fail to display the fetched data?
- A. Use Data JSON is Not selected in the properties of the Type Ahead Block.
- B. FirstName, LastName, and BirthDate are not placed inside the Type Ahead Block.
- C. The typeHead key is not in the correct format.
- D. Lookup Mode is selected in the properties of the Type Ahead Block.
Answer: B
NEW QUESTION # 58
What two advantages does a DataRaptor Turbo Extract have over a standard DataRaptor Extract?
Choose 2 answers
- A. It populates data in PDF and DocuSign format
- B. It is easier to configure
- C. It supports complex field mappings
- D. It has better performance at runtime
Answer: B,D
NEW QUESTION # 59
Refer to the exhibit.
All inputs to the Calculation Matric are set correctly.
The Calculation Matrix has the following input:
What is the output?
- A. 12.99,13.99
- B. 12.99
- C. Null
- D. 13.99
Answer: B
NEW QUESTION # 60
Refer to the exhibit.
A developer creates an OmniScript display FirstName, LastName, and BirthDate of a contact using a Type Ahead Block. The DataRaptor used in the Type Ahead has been tested and fetches the correct data.
When previewing Omniscript, the developer enters a name in the Type Ahead and makes a selection of a contact from the list. However, the text fields FirstName. LastName, and BirthDate are not getting populated with the data.
What is the reason that the fields fail to display the fetched data?
- A. Use Data JSON is not selected in the properties of the Type Ahead Block.
- B. Lookup Mode is not selected in the properties of the Type A Head Block.
- C. FirstName, LastName, and BirthDate are not placed inside the Type ahead Block.
- D. The Typeghead ley is not in the correct format
Answer: C
NEW QUESTION # 61
......
Pass OmniStudio-Developer Tests Engine pdf - All Free Dumps: https://pass4sure.itexamdownload.com/OmniStudio-Developer-valid-questions.html